BIT 7BIT 6BIT 5BIT 4BIT 3BIT 2BIT 1BIT 0
BYTE 0
GENERAL PURPOSE
ReservedPrinter Cover is open (FP-700)General error - OR of all errors marked with ''Failure in printing mechanismDisplay is disconnectedThe clock needs setting Code of incoming command is invalid Incoming data has syntax error
BYTE 1
GENERAL PURPOSE
ReservedNot usedPrinter cover is open RAM failure after power ONBattery is low (FP-700) Operational memory was cleared Command cannot be performed in the current fiscal mode During command some of the fields for sums overflow.
BYTE 2
GENERAL PURPOSE
ReservedElectronic Journal (EJ) is not emptya non-fiscal receipt has been openedElectronic Journal (EJ) or paper near endA fiscal receipt has been openedElectronic Journal (EJ) end or no paperPaper near end No paper.
BYTE 3
STATUS OF SWITCHES
ReservedSW7 ON. Serial port speed.SW6 ON. Serial port speed.SW5 ON. Presenter Active.SW4 ON. Automatic paper cutting.SW3 ON. Half cutting (FP-700) or Transparent displaySW2 ON. No obligatory display.SW1 ON. Transparent display (FP-700) Automatic paper cutting.
BYTE 4
FISCAL MEMORY
ReservedPrinter Head Overheating.OR of all mistakes marked by '' from bytes 4 and 5. Fiscal memory is fully engaged.Not more than 30 entries in the FM.Serial number set / no FM TIN and VRN numbers set (FP-700) When there is an error during entry in FM
BYTE 5
FISCAL MEMORY
ReservedReservedError reading FM (FP-700) Serial number setTax rates have been enteredFiscal printer is in fiscal modeLast fiscal closure (Z report) not OKFM has been formatted FM is in "read-only" mode